Industrial CFD
Choosing CFD software for industrial R&D: OpenFOAM, Fluent and STAR-CCM+
Picking between OpenFOAM, Ansys Fluent and STAR-CCM+ is not a licensing question. What matters is who will run and maintain the process, what support you can count on and which physics you need to solve. This article sets out the project data to collect, a weighted decision matrix and a benchmark built on verification and validation.

In this article
- Project data to gather before choosing
- OpenFOAM licences and distributions
- Total cost of ownership
- Who keeps the process alive over time
- Configure, extend or write a solver
- Automation versus changing the physics
- A decision matrix for CFD software
- A worked example with two weighting profiles
- A fair benchmark, verification and validation
- Requirements and data to bring to Cubit
The choice between OpenFOAM, Ansys Fluent and Siemens Simcenter Star-CCM+ is often reduced to a question of licensing: one free package on one side, two paid ones on the other. For an R&D department that will rely on its simulation process for years, other factors weigh more: the skills available in-house, the maintenance of the code, the support behind it and the physics that has to be solved. This article gives decision makers the project information to collect, the items that make up total cost and a criterion for deciding when to move from configuring a solver to customising it.
There is no universal winner. What follows is a decision matrix with weights to be set by your own project, a worked example in which the weights change the outcome, and a benchmark with verification and validation that makes the three packages comparable with one another and with experimental data. The examples are hypothetical and declared as such: they do not describe Cubit projects or measurements.
Project data to gather before choosing
Six pieces of information come before any software. The physics covers flow regime, turbulence, conjugate heat transfer, multiphase flow, rotating parts and reactions. Geometry matters together with how often it changes: a CAD model that changes every week rewards guided mesh preparation, while a stable geometry with many parametric variants rewards automation. Computing volume is measured in cases per year, cells per case and cores available.
Validation data tells you which measurements exist, with what uncertainty, and how much deviation the project can tolerate. The organisation defines who runs the simulations and with what C++ or Python skills. Finally there are external constraints: traceability, confidentiality, delivering a tool to a customer, and integration with the CAD and product lifecycle management (PLM) systems already in use.
As a hypothetical example, consider an R&D department of six engineers working on a hydraulic component with a stable geometry, a few hundred variants a year, test data from two prototypes and an interface phenomenon that standard models capture only in part.
OpenFOAM licences and distributions
OpenFOAM is not a single product. The OpenFOAM Foundation publishes on openfoam.org the version developed by CFD Direct, with sequential numbering: v14 was released on 14 July 2026. OpenCFD, a company its own website describes as wholly owned by Keysight, publishes on openfoam.com a version numbered by date, with two releases a year, in June and December; when consulted in October 2026 the latest was v2606. Both are released under the GPL.
For anyone choosing, v14 and v2606 are not two snapshots of the same line: they are two distributions, whose solvers, models and dictionaries can differ. A model written for one may need porting to the other, and results are not necessarily reproducible between the two. Whoever sets up the comparison states distribution, version and build, and decides beforehand which distribution goes into the comparison with the commercial packages.
OpenCFD’s licensing page spells out the practical consequence of the GPL: anyone who distributes binaries must make the source available, whereas internal use does not oblige you to publish your own modifications. A derived solver that leaves the company, for instance one delivered to a customer, should be checked with your legal department. On the commercial side, the Siemens page mentions the Power Session and Power on Demand licensing schemes, while the Ansys page for Fluent gives no licensing terms. None of the three pages lists prices: ask the vendors with the same usage scenario, together with how the licence scales with cores and GPUs.
Total cost of ownership
Total cost, calculated over a horizon equal to the life of the simulation process (three to five years, say), adds up licences, computing, working hours, support and maintenance of in-house code. With OpenFOAM the solver licence (GPL) carries no fee, while the hours depend on how much meshing, post-processing and automation work stays with the team and on which optional tools or services are added; in the comparison, the solver licence and these services sit on separate lines. How much the hours weigh is settled by the times measured in the benchmark, because no rule holds for every workflow. With Fluent and STAR-CCM+ the licence is an item to negotiate, and it must be read together with the planned number of cores and users.
In the R&D department of our example, one extra hour of preparation per case becomes hundreds of hours a year, to be set against the fee avoided; the comparison only means something with the times measured in the benchmark. The same goes for computing: the Fluent page describes a native pressure-based GPU solver, the STAR-CCM+ page describes scalability across GPUs, CPUs and ARM, and the OpenFOAM v2606 release announcement mentions community-contributed GPU support. What they are worth on your case is established on identical hardware.
Who keeps the process alive over time
In OpenFOAM, cases are defined by text files and the source is accessible; openfoam.org puts the code base at roughly 1.5 million lines of C++. Support is bought: OpenCFD offers support, code development and engineering services, CFD Direct offers training. Fluent and STAR-CCM+ offer an integrated interface, with guided meshing workflows in Fluent and a single environment from pre-processing to visualisation in STAR-CCM+, and a vendor to turn to.
Maintenance weighs in all three cases, but it falls on different shoulders. At every new release the regression cases are rerun and the in-house code is rechecked: Fluent user-defined functions (UDFs), STAR-CCM+ Java macros, OpenFOAM C++ libraries. Ask the vendor, or the internal team, who steps in, and how quickly, if the solver diverges a few days before a deadline.
Configure, extend or write a solver
Customisation has three levels. The first is configuring an existing solver: turbulence model, boundary conditions, numerical schemes, monitors and launch scripts. The second is extending it through the extension points the software provides, that is UDFs in Fluent, C++ libraries loaded by the case in OpenFOAM and, in STAR-CCM+, whatever extension capabilities the vendor documents for the version in use. The third is a new solver, needed when the equations or the coupling exist in no code at all.
You move up a level when validation demands it. In our R&D department the first step is to try the standard models of the three packages on the measured prototype: if the deviation on the quantity of interest falls within tolerance, configuration is enough. If the deviation exceeds tolerance in all three, that alone does not prove the model is inadequate.
First check numerical verification (convergence of the monitored quantities and discretisation error), the data and boundary conditions, the uncertainty of the measurement and of the input parameters, and whether the chosen physics is appropriate. Extending a model is justified if, with these factors ruled out, the deviation still exceeds tolerance and the cause traces back to a phenomenon the available models do not represent. OpenFOAM is the better choice when you need access at the level of the equations, when the tool must run outside the laboratory without per-seat licences, or when the number of cases makes licensing the dominant cost. A commercial environment is the better choice when the standard model is enough or when nobody is available to maintain numerical code, because then vendor support covers part of the risk.
Every customised model needs a regression case, documented validation and an owner with a deputy.
Automation versus changing the physics
Automation and changing the physics are different jobs. The Python plugins in v2606 (pybFoam and pyOFTools) and PyFluent, which according to its documentation serves to set up, run and monitor simulations and extract their results, drive the workflow and add no equations; the same is true of STAR-CCM+ Java macros when they automate operations of the software. A new model or an extra term in an equation goes instead through the solver’s extension points, that is UDFs in Fluent and C++ libraries in OpenFOAM, while for STAR-CCM+ you check in the vendor documentation what the version in use allows you to change in the physical model.

A decision matrix for CFD software

| Criterion | Question to ask | Favours OpenFOAM if | Favours Fluent or STAR-CCM+ if |
|---|---|---|---|
| Skills required | Who runs and who maintains the cases? | the team has numerical methods, Linux and C++ | the team is made of product engineers on tight deadlines |
| Customisation | Does the model already exist? | you need access to the equations | UDFs, macros or APIs are enough |
| Automation | How many variants a year? | the pipeline is written with your own tools | built-in automation is enough |
| Maintenance | Who reruns the tests at every release? | there is a code owner | the support contract and regression tests confirm compatibility between releases |
| Support | Who answers when a deadline looms? | a contract or a partner is enough | you need the software vendor |
| Licences | How does cost scale with cores and users? | per-seat cost is high | the contract model is acceptable |
| HPC | Does the solver scale on the available cluster? | the code is verified on many cores | scalability is proven on the case |
| Overall cost | What do hours and licences cost over three to five years? | the hours are already available | the hours are the constraint |
A worked example with two weighting profiles
The method has three steps: assign the criteria weights summing to 100, give each package a score from 0 to 5, and multiply scores by weights. Scores come from the benchmark, with thresholds fixed before the test, for instance on the deviation from measurement or on preparation hours. An example with abstract numbers shows that the outcome depends on the weights. Option 1 is highly customisable but demanding in skills, Option 2 is integrated. Profile A is that of a team of product engineers, Profile B that of a team that has to extend a model and distribute the tool.
| Criterion | Weight A | Weight B | Option 1 | Option 2 |
|---|---|---|---|---|
| Skills required | 25 | 5 | 2 | 4 |
| Support | 20 | 5 | 2 | 4 |
| Automation | 15 | 15 | 3 | 4 |
| Maintenance | 10 | 5 | 2 | 4 |
| HPC | 10 | 15 | 4 | 4 |
| Overall cost | 10 | 10 | 4 | 3 |
| Licences | 5 | 15 | 5 | 2 |
| Customisation | 5 | 30 | 5 | 2 |
With weights A, Option 1 scores 2.85 and Option 2 scores 3.70. With weights B, and the same scores, Option 1 scores 4.00 and Option 2 scores 3.00. Weights and scores are illustrative and describe no real software. The R&D department of our example, with a standard model out of tolerance and test data available, resembles Profile B; if the standard model fell within tolerance, it would resemble Profile A.
A fair benchmark, verification and validation
A fair benchmark starts from a single case: same geometry, same boundary conditions, same class of physical models, same hardware. Each solver gets its own mesh, built with that software’s best practice and refined over at least three levels. The NASA Glenn page on spatial convergence, which summarises Patrick Roache’s method, recommends three grids, a refinement ratio of no less than 1.1 and a safety factor of 1.25 for the grid convergence index (GCI) with three or more grids. Convergence is judged on the monitored quantities, such as forces and flow rates, as well as on residuals.
Verification and validation answer different questions. Verification checks that the equations are solved correctly, and the GCI estimates the discretisation error. Validation checks that the equations are the right ones, by comparing the solution with data. The ASME V&V 20-2009 standard, reaffirmed in 2021, frames it at a validation point, with the numerical, experimental and input-parameter uncertainties; accuracy at the other points of the domain remains an engineering judgement. This is why each package is compared with the measurement and not with the other two.
The benchmark also records computing time at equal core count, preparation hours, failed cases and reproducibility between two operators. Distribution, version, build and settings are noted, and among the settings the defaults are kept separate from the tuned ones.
Requirements and data to bring to Cubit
In its CFD consulting work Cubit uses STAR-CCM+, Ansys Fluent and OpenFOAM, as the service page states. Anyone setting up this choice can discuss project requirements and data with Cubit before committing to licences or development. The six items described at the start are enough, even in preliminary form: with them the matrix is filled in with your own weights and the verification and validation benchmark is defined.
Text prepared with the help of artificial intelligence and reviewed by Cubit.
What to take into the project
Choosing CFD software takes criteria weighted on your own project and a benchmark compared against measurement, not a universal winner.
Have a design problem to dig into? Compare requirements and available data with the Cubit team.
Talk to Cubit