Thermal management in power electronics: preventing hotspots with thermo-fluid simulation

Industrial CFD

Thermal management in power electronics: preventing hotspots with thermo-fluid simulation

A hotspot is a local temperature maximum that can exceed the component limit while the average stays acceptable. Coupled simulation of conduction and flow locates it before the prototype, within the uncertainty of the model.

Technical article · 10 minute read

Four thermal images of a board with an oven-controlled crystal oscillator: the oscillator area is yellow and white, with spots above 75 °C, while the surrounding board stays purple and blue, with a colour bar in °C.
Thermal images of a Rakon STP2734B LF oven-controlled oscillator (OCXO) on a board. Surface temperatures, not junction temperatures; the oscillator is deliberately heated by its own oven. Image: Wikimedia Commons, Mister rf, CC BY-SA 4.0, via Wikimedia Commons.
In this article

In power electronics thermal management, a hotspot is a local temperature maximum, higher than the average temperature of the device, and it can exist even within the component’s limits. It becomes a risk when that maximum exceeds the component limit while the average remains acceptable. A simulation couples conduction in the solids with the flow of the cooling fluid. It makes it possible to locate the hotspot before the prototype, within the uncertainty of the model, and to compare layout, thermal interface and cooling circuit variants on the same computational basis. The result is an estimate with an uncertainty that can be measured and reduced, not the exact temperature of a component.

Three terms get confused. The hotspot depends on the heat path from source to fluid. Junction temperature is the quantity the semiconductor manufacturer limits. Thermal runaway in a lithium cell is a chain of exothermic reactions that, once triggered, feeds itself. From this the reader learns what to ask of the simulation, which data to collect and which checks to demand before modifying an inverter, a converter or a battery pack.

Hotspot, junction temperature and thermal runaway

Junction temperature in the model

Thermal CFD computes the temperature field in the module, the heat sink and the fluid, but the presence of a source in the model is not enough to read the junction temperature off that field. It depends on how the source is represented. If the die is resolved with its geometry and the power is assigned to the active region, the model gives the temperature of that region, and you state whether you read the maximum or the average. When the package is replaced by a compact model or a thermal network, the junction is a node of the network: its temperature is an estimate, valid within the model’s assumptions and parameters.

With a source modelled as a block of uniform volumetric power, the model does not capture the real junction. The value read is that of the block, to be declared as a reference quantity, and comparison with the junction limit requires a package model or a measurement. Preventing a hotspot and respecting the junction limit are related but distinct goals, because a device can have an acceptable average temperature and exceed the limit at one point.

JESD51 tests and manufacturer data

The JEDEC JESD51 series of tests measures junction-to-ambient resistance on a standardised test board, and JESD51-2A sets the environment as still air. Texas Instruments application note SPRA953D (March 2024 revision), which summarises those tests, observes that the value serves to compare one package with another and not to calculate the junction in an application. It depends on the board: in still air, 70 to 95% of the power leaves through the test board rather than the package. For the same reason the note advises against deriving the junction from case temperature using the junction-to-case resistance. It points instead to the ΨJT parameter (JESD51-2), which is not a true thermal resistance and is not used when a heat sink is planned.

JESD51-14, according to its published title and scope, covers the junction-to-case resistance of devices with a single heat flow path: it derives it from the junction temperature alone, with two transient measurements in which the interface resistance on the case changes, and it requires no thermocouple on the case. Manufacturer data therefore enters the model as a starting point to be correlated with testing.

Thermal runaway in a battery pack

Thermal runaway in a battery pack belongs to another category. The review by Xuning Feng and colleagues (Energy Storage Materials, 2018) calls it the key scientific problem in the safety of lithium-ion batteries for electric vehicles. A thermal CFD with the heat generation of normal operation contains none of the abuse chemistry, gas venting or cell-to-cell propagation. It therefore does not certify the safety of a pack: that requires abuse tests.

Input data for power electronics thermal management

The main input is the dissipated power, which has several components: conduction losses in the devices, switching losses that grow with frequency, diode recovery, Joule heating in busbars and windings, core losses in magnetic components. They come from measured maps or manufacturer models, as functions of current, bus voltage, frequency and temperature, and are assigned to the region that generates them: the chip volume, the bonding wire, the busbar. A global value spread over the package shifts the peak and erases the gradient you want to study.

Losses in turn depend on temperature: the on-resistance of a MOSFET rises as it heats up, and the voltage drop of IGBTs and diodes also varies with temperature and current. The calculation is therefore coupled: the thermal field updates the losses and the losses update the field, until convergence.

Operating conditions form a mission profile, not a single point. A traction inverter alternates continuous power, short accelerations and stops, and the peak may fall in a transient, when the thermal capacities have not yet levelled the gradients. The transient calculation also yields a reduced-order model to plug into a system simulation. Ansys Icepak and Siemens Simcenter STAR-CCM+ are two of the available codes: the Ansys page mentions conjugate heat transfer, DC Joule heating and liquid cooling, the Siemens page flows and heat transfer, with a lithium battery case.

From solid to fluid, through the contacts

Six blocks in series, from chip to fluid, with a downward heat arrow and three notes: power source, contact resistance, convection.
Heat passes in series through chip, substrate, baseplate, interface layer, cold plate and fluid; contact resistance is the uncertain input. Illustrative diagram, not a Cubit simulation result.

Heat passes in series through the chip, the substrate, the baseplate, the interface layer, the heat sink or cold plate and finally the fluid. The conjugate calculation solves conduction in every layer and convection on the wetted surface in the same system. As a result the heat transfer coefficient is an outcome of the flow, not an assumed input. Where two solids touch, contact resistance appears, which depends on clamping pressure, roughness, the thickness of the thermal interface material layer (the bond line) and its age. It varies from unit to unit, and it is an uncertain input that can be calibrated against testing.

Properties too must be taken at operating temperature. The conductivity of silicon falls with temperature, and the viscosity of a water-glycol mixture varies with it, which affects how the flow splits between channels. In pouch cells, in-plane and through-thickness conductivity differ and both must be measured.

An inverter module on a cold plate

The example is illustrative: the values are chosen to show the reasoning. A three-phase inverter dissipates 2.4 kW in its power modules, mounted on a plate fed at 8 L/min with a water-glycol mixture. The mixture’s specific heat and density are 3.4 kJ/(kg K) and 1.07 kg/L. The mass flow rate is about 0.143 kg/s and the energy balance gives a fluid temperature rise of about 5 K between inlet and outlet. Downstream modules receive warmer fluid than upstream ones and, with the same junction limit, have less margin: the last module starts from fluid up to 5 K warmer, and all else being equal its computed temperature rises by the same amount.

The coupled calculation shows whether the hottest module is still the last in the circuit when the path is reversed, a module changes position or the interface layer is at the thick end of its tolerance. A change that lowers the peak by less than the model uncertainty is not yet a decision; it becomes one when the predicted difference between two variants exceeds the estimated uncertainty of the comparison.

Air or liquid

In forced convection a liquid removes far more heat than air per unit area, which is why it takes over above a certain power density. The choice, however, rests on four quantities: maximum temperature and uniformity between components improve with flow rate, while pressure drop and the auxiliary power of fans or pumps get worse. In turbulent flow the pressure drop grows roughly with the square of the flow rate. Pump power is the product of pressure drop and volumetric flow rate, divided by efficiency. CFD provides the pressure drop curve of the real circuit and the operating point that meets the temperature limit with the least auxiliary power.

With air, natural convection, recirculation inside the enclosure and radiation matter, and simplified boundary conditions neglect them. With liquid, what matters is the split of flow between parallel channels and the stability of the inlet temperature.

Power electronics versus battery pack

In power electronics the sources are small and concentrated, with high heat flux density, and the thermal response is fast. In a pack the sources are spread across the cells, the power per cell is modest and the response is slow, because of the large thermal mass. The model by Bernardi, Pawlikowski and Newman (Journal of the Electrochemical Society, 1985) is the reference for the heat generation of a cell. It includes Joule heating and the heat of the electrochemical reaction. A cell’s source depends on operating conditions, and it is better characterised by testing than read from a datasheet.

The objective changes too. For a module the junction peak matters; for a pack the temperature difference between cells also matters, because the hottest cell sets the limit for the whole pack. An adequate model represents anisotropic conductivity, the contacts with the cooling plates and the flow differences between channels.

List of five checks: three-level mesh, energy balance, input sensitivity, comparison with testing, comparison between predicted difference and uncertainty.
The decision comes after the checks: a variant counts only if the predicted difference exceeds the estimated uncertainty. The list imposes no fixed order. Illustrative diagram, not a Cubit simulation result.

Checks before changing the design

Mesh and energy balance

On the mesh, thin interface layers need cells through their thickness or a contact resistance model, and the channel walls need a treatment consistent with the first-cell distance. Mesh dependence is quantified with at least three meshes of increasing refinement: Celik and colleagues (Journal of Fluids Engineering, 2008, DOI 10.1115/1.2960953) describe the apparent order of convergence, Richardson extrapolation and the grid convergence index. For three meshes the safety factor is 1.25. The numerical uncertainty of the quantity on which the decision rests is reported.

The energy balance checks that the power put in is found again in the enthalpy rise of the fluid and in the losses to the environment; the discrepancy is reported. A small numerical residual does not guarantee a closed balance, and convergence is also judged on the quantities monitored at the critical points.

Input uncertainty and comparison with testing

On the inputs, contact resistance, losses, flow rate and fluid properties have tolerances, and a sensitivity analysis shows which ones dominate the result. The ASME V&V 20-2009 standard for CFD and heat transfer describes how to compare simulation and experimental data at a validation point and how to combine numerical, parameter and measurement uncertainties; accuracy at the other points remains a matter of engineering judgement.

The comparison with testing uses temperatures measured with embedded thermocouples, temperature-sensitive electrical parameters for the junction, and thermography with known emissivity. Flow rate, inlet temperature and pressure drop are added, under the same conditions as the model.

Numerical-experimental correlation appears among the activities on Cubit’s CFD consulting page. The 2025 company presentation reports two thermal analysis cases. In the first, Cubit developed for an automotive customer a numerical procedure to predict the thermal performance of brakes; the presentation states the aim as correlating simulation results with the customer’s tests and developing a reduced-order model to contain computing cost, and it documents neither the outcome of the correlation nor the calibrated parameters.

In the second, Cubit carried out thermal CFD analyses on the boards of an air monitoring device, from concept to final design, in support of the test campaign. Where a test exists, correlation makes it possible to calibrate the uncertain parameters, such as contact resistance, and to establish the range within which the comparison between variants is valid.

Data for a technical assessment

To assess whether power electronics thermal management can be supported by simulation you need: the geometry of modules, busbars and cooling circuit, with the electronic layout data (ECAD) if the board is part of the thermal path; device losses as functions of current, voltage, frequency and temperature, with the mission profile; materials and interfaces with thickness, clamping pressure and datasheet; fluid, flow rate, inlet temperature and pressure drop budget; the limits to be met, junction or cell and cell-to-cell difference; existing measurements, with sensor positions and test conditions. Finally, the decision the simulation has to support and the acceptable tolerance on temperature. If an input is uncertain, the first step is a test that calibrates it.

Text prepared with the help of artificial intelligence and reviewed by Cubit.

What to take into the project

Power electronics thermal management is decided on the heat path from chip to fluid and on an estimate with a verified uncertainty.

Have a design problem to dig into? Compare requirements and available data with the Cubit team.

Talk to Cubit